En Approval Addressable Fire Alarm System
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Type: | Fire Alarm Host |
| Function: | Networked |
Gold Member Since 2012
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Address
55 Yunhui Road, Yunlong Town, Yinzhou district, Ningbo, Zhejiang, China 315137
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW
Terms of Payment
T/T, PayPal, Western Union
Find Similar Products
Basic Info.
- Usage
- Door, Window, Fire, Smoke
- Certification
- CE, UL, En
- Alarm Volume (within 1m)
- ≥80dB
- Networking Mode
- Wired
- Addressable Loops
- 1
- Number of Connected Devices Per Loop
- 125
- Loop Current(Max)
- 400 Ma
- Programmable Sounder Groups(Max)
- 512
- Number of Networked Panels
- 4
- Transport Package
- 6PCS/CTN
- Specification
- 420*337*99mm
- Trademark
- Numens
- Origin
- Ningbo, China
- HS Code
- 8531100000
- Production Capacity
- 50, 000PCS/Month
Product Description
The analogue addressable control and indicating equipment forms the central part of a fire detection and alarm system. The fully networkable 2-wire 6000 is compatible with Numens addressable devices and can also be connected to non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile cause-and-effect PC-based programming tool enables rapid customization with software for sites that require special operating features.
The 6000 comes standard with features that allows flexibility and expandability.
Features:
·Single loop or 2-loop options available
·Networkable,up to 4 control panels
·Up to 125 addressable devices
·Automatic device detection on start-up
·Automatic device type-code verification
·2 independently programmable non-addressable A/V alarm output circuits
·2 programmable Fire Alarm relay outputs
·Fault relay output
·Backlit LCD display providing 4 rows of 40 characters
·16 zone fire alarm LED indicators
·3000 event history log
Specification:

FAQ:
Q1:Are you a manufacturer or trading company?
A1:Numens is a professional fire alarm system manufacturer.
Q2:What kind of production service do you provide?
A2:The whole fire alarm system,include Addressable system, Conventional system, Residential system and so on....
Q3:What kind of certification do you have?
A3:Numens was EN,BSI,UL,SGS certified and all the products were produced under these major international standard .
Q4:What is the lead time for new order?
A4:The lead time for new order is 25 days after confirm order.
Q5:How do I get price information?
A5:Sales representatives are responsible for providing detailed price information within 1 workday after get your inquiry.
Approvals:
Standards and approvals are important to Numens, giving customers additional confidence about the performance and reliability of the entire product range. The whole Numens development and production processes are certified to ISO 9001:2015. Products carry approvals to major European and North American Standards, with more than 70% holding CE, UL, LPCB, KITEMARK, CSIRO and CCC certifications.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile cause-and-effect PC-based programming tool enables rapid customization with software for sites that require special operating features.
The 6000 comes standard with features that allows flexibility and expandability.
Features:
·Single loop or 2-loop options available
·Networkable,up to 4 control panels
·Up to 125 addressable devices
·Automatic device detection on start-up
·Automatic device type-code verification
·2 independently programmable non-addressable A/V alarm output circuits
·2 programmable Fire Alarm relay outputs
·Fault relay output
·Backlit LCD display providing 4 rows of 40 characters
·16 zone fire alarm LED indicators
·3000 event history log
Specification:
| operating voltage | AC(85~260)V/50/60Hz |
| power supply | 2.2A@DC 28V |
| standby battery capacity(2xDC 12V) | 7.2Ah |
| addressable loops | 1 or 2 |
| number of connected devices per loop | 125 |
| loop current(max) | 400mA |
| sounder driver | 800mA |
| programmable sounder groups(max) | 512 |

FAQ:
Q1:Are you a manufacturer or trading company?
A1:Numens is a professional fire alarm system manufacturer.
Q2:What kind of production service do you provide?
A2:The whole fire alarm system,include Addressable system, Conventional system, Residential system and so on....
Q3:What kind of certification do you have?
A3:Numens was EN,BSI,UL,SGS certified and all the products were produced under these major international standard .
Q4:What is the lead time for new order?
A4:The lead time for new order is 25 days after confirm order.
Q5:How do I get price information?
A5:Sales representatives are responsible for providing detailed price information within 1 workday after get your inquiry.
Approvals:
Standards and approvals are important to Numens, giving customers additional confidence about the performance and reliability of the entire product range. The whole Numens development and production processes are certified to ISO 9001:2015. Products carry approvals to major European and North American Standards, with more than 70% holding CE, UL, LPCB, KITEMARK, CSIRO and CCC certifications.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Addressable fire alarm Control System
- En Approval Addressable Fire Alarm System
Related Categories
Hot Searches
More