2-Wire, 12/24V, Flame Detector

Product Details
Customization: Available
Type: Sensor
Usage: Detecting Flame
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2011-07-06
Management System Certification
ISO9001:2008
  • 2-Wire, 12/24V, Flame Detector
  • 2-Wire, 12/24V, Flame Detector
  • 2-Wire, 12/24V, Flame Detector
  • 2-Wire, 12/24V, Flame Detector
  • 2-Wire, 12/24V, Flame Detector
  • 2-Wire, 12/24V, Flame Detector
Find Similar Products

Basic Info.

Installation Mode
Ceiling Mounted
Certification
CE, ISO
Application
Home, Industry, Communication Electronic Products, Special Equipment, Security and Fire Industry
Operating Voltage
DC(12/24)V
Sampling Time
(2~4)S
Reset Time
<5s
UV Sensitivity
(185~260)Nm
Transport Package
100PCS/CTN
Specification
dia. 102*45mm
Trademark
NUMENS
Origin
Ningbo
HS Code
8531100000
Production Capacity
50, 000PCS/Month

Product Description

The 401 non-addressable ultra-violet flame detectors are suitable for connection to 2-wire and 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept non-addressable type detectors.
The 401 UV flame detectors are suited to applications where flames rapidly develop due to the nature of the combustible materials, such as where petrochemical products are used or stored.

Features:

·    High sensitivity UVtron sensor tube technology
·    Solar blind, with an electronic filter to eliminate unwanted alarms from naturally occurring phenomena
·    High immunity to electrical noise and RF interference
·    Fast response time
·    Wide field of view
·    Polarity insensitive
·    2-wire and 4-wire models for DC 12 V and DC 24 V operation
·    4-wire models available with a N/O alarm relay output
·    4-wire models available with auto-reset
·    2-wire models available with remote LED output
·    Connects to zone monitor for use with addressable control and indicating equipment

Specification:
operating voltage DC(12/24)V
start-up time ≤30s
quiescent current 30μA
sampling time (2~4)s
alarm condition indicator Dual red LEDs
reset voltage ≤1V
reset time ≤5s
field of view 120°cone

Ordering Information:
Part Number 2-Wire 4-Wire Remote Indicator Relay Output Auto Reset
401-001 - - - -
401-002 - - -
401-003 - - -
401-004 - -


2-Wire, 12/24V, Flame Detector
About Numens

Formed in 2010, Numens is an emerging supplier of professional safety products for fire detection and alarm systems. Numens supplies an extensive range of addressable, non-addressable and residential products for life safety and property protection applications. Offering over 150 products and supplying to more than 100 customers around the globe, we are committed to establishing long-term relationships with our customers and suppliers.
 
Mission and Values
Our mission is to provide building owners with high quality, inexpensive fire detection and related equipment that will protect lives of building occupants and minimize damage to buildings through early detection and warning of a fire emergency.
Our engineers, production and support staff will design, manufacture and deliver products with performance and quality to always delight our customers.
Success in our future depends on the integrity and ethical behaviour of all our employees. We support and nourish our staff to improve and grow as responsible members of a civil society. We take personal responsibility for our actions and respect others with different views, as we continually strive for improvements for our customers, our company and ourselves.
 
Capabilities
Sales, engineering and production are located in Ningbo, China; just 2 hours south of Shanghai. Our Ningbo site has 10,000 m2 (100,000 ft2) of floor-space. From product concept, electrical and mechanical design, we can provide the solutions to detection needs. Our manufacturing is vertically integrated, with our capabilities including tool-making, plastic injection moulding, SMT manufacturing, and final assembly and test.
You can view our product range on our website or in our product catalogue (document number 34-0001).
 
Standards and Approvals
Standards approvals are important to us, giving customers additional confidence of the performance and reliability of our products. We are certified to ISO 9001:2008 and our products carry approvals to major European and North American Standards.



FAQ:
Q1:Are you a manufacturer or trading company?
A1:Numens is a professional fire alarm system manufacturer.
 
Q2:What kind of production service do you provide?
A2:The whole fire alarm system,include Addressable system, Conventional system, Residential system and so on....
 
Q3:What kind of certification do you have?
A3:Numens was EN,BSI,UL,SGS certified and all the products were produced under these major international standard .
 
Q4:What is the lead time for new order?
A4:The lead time for new order is 25 days after confirm order.
 
Q5:How do I get price information?
A5:Sales representatives are responsible for providing detailed price information within 1 workday after get your inquiry.

2-Wire, 12/24V, Flame Detector2-Wire, 12/24V, Flame Detector2-Wire, 12/24V, Flame Detector2-Wire, 12/24V, Flame Detector2-Wire, 12/24V, Flame Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier