Conventional (non-addressable) 2-Wire Fire Alarm Control Panel

Product Details
Customization: Available
Type: Fire Alarm Host
Function: Networked
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2011-07-06
Management System Certification
ISO9001:2008
  • Conventional (non-addressable) 2-Wire Fire Alarm Control Panel
  • Conventional (non-addressable) 2-Wire Fire Alarm Control Panel
  • Conventional (non-addressable) 2-Wire Fire Alarm Control Panel
  • Conventional (non-addressable) 2-Wire Fire Alarm Control Panel
  • Conventional (non-addressable) 2-Wire Fire Alarm Control Panel
  • Conventional (non-addressable) 2-Wire Fire Alarm Control Panel
Find Similar Products

Basic Info.

Usage
Door, Window, Fire, Smoke
Certification
CE, UL, En
Alarm Volume (within 1m)
≥80dB
Networking Mode
Wired
Wiring Mode
Sub-Line System
Operating Voltage
AC(85~260)V/50/60 Hz
Alarm Zone Circuits
2,4,8 or 16
Number of Connected Devices Per Zone
32
Alarm Zone Quiescent Current
5mA
Number of Programmable Output Relays
2
Transport Package
6PCS/CTN
Specification
CE
Trademark
Numens
Origin
Ningbo, China
HS Code
853110000
Production Capacity
50000 Per Year

Product Description

The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm system. The 2-wire 4001 is compatible with Numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming facilitates out-of-box installation and rapid commissioning. 


Features:

 ·    2, 4, 8, or 16 detection zones
·    Up to 32 non-addressable devices per alarm zone circuit
·    Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
·    3 Access Levels
·    Single-person test mode
·    Day/night mode
·    Manual activation of audio/visual alarm devices
·    Supervised auxiliary DC 24 V output
·    2 independently programmable non-addressable A/V alarm output circuits
·    2 programmable Fire Alarm relay outputs
·    Fault relay output
·    3 voltage-free inputs for remote reset, evacuation start/stop, and Day/Night mode
·    Supports up to 7 Repeater Panels

Ordering Information:
Part Number 2-Zone 4-Zone 8-Zone 16-Zone
4001-01 - - -
4001-02 - - -
4001-03 - - -
4001-04 - - -
 

Conventional (non-addressable) 2-Wire Fire Alarm Control Panel
About Numens

Formed in 2010, Numens is an emerging supplier of professional safety products for fire detection and alarm systems. Numens supplies an extensive range of addressable, non-addressable and residential products for life safety and property protection applications. Offering over 150 products and supplying to more than 100 customers around the globe, we are committed to establishing long-term relationships with our customers and suppliers.
 
Mission and Values
Our mission is to provide building owners with high quality, inexpensive fire detection and related equipment that will protect lives of building occupants and minimize damage to buildings through early detection and warning of a fire emergency.
Our engineers, production and support staff will design, manufacture and deliver products with performance and quality to always delight our customers.
Success in our future depends on the integrity and ethical behaviour of all our employees. We support and nourish our staff to improve and grow as responsible members of a civil society. We take personal responsibility for our actions and respect others with different views, as we continually strive for improvements for our customers, our company and ourselves.
 
Capabilities
Sales, engineering and production are located in Ningbo, China; just 2 hours south of Shanghai. Our Ningbo site has 10,000 m2 (100,000 ft2) of floor-space. From product concept, electrical and mechanical design, we can provide the solutions to detection needs. Our manufacturing is vertically integrated, with our capabilities including tool-making, plastic injection moulding, SMT manufacturing, and final assembly and test.
You can view our product range on our website or in our product catalogue (document number 34-0001).
 
Standards and Approvals
Standards approvals are important to us, giving customers additional confidence of the performance and reliability of our products. We are certified to ISO 9001:2008 and our products carry approvals to major European and North American Standards.



FAQ:
Q1:Are you a manufacturer or trading company?
A1:Numens is a professional fire alarm system manufacturer.
 
Q2:What kind of production service do you provide?
A2:The whole fire alarm system,include Addressable system, Conventional system, Residential system and so on....
 
Q3:What kind of certification do you have?
A3:Numens was EN,BSI,UL,SGS certified and all the products were produced under these major international standard .
 
Q4:What is the lead time for new order?
A4:The lead time for new order is 25 days after confirm order.
 
Q5:How do I get price information?
A5:Sales representatives are responsible for providing detailed price information within 1 workday after get your inquiry.

Conventional (non-addressable) 2-Wire Fire Alarm Control PanelConventional (non-addressable) 2-Wire Fire Alarm Control PanelConventional (non-addressable) 2-Wire Fire Alarm Control PanelConventional (non-addressable) 2-Wire Fire Alarm Control PanelConventional (non-addressable) 2-Wire Fire Alarm Control Panel

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier