4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset

  • Audited Supplier
  • 15 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Advanced Photoelectric Sensing: Utilizes photoelectric smoke sensing chamber and electronic thermistor for early fire detection.
  • High Immunity Against False Alarms: Advanced electronics provide high immunity against unwanted alarms for reliable performance.
  • Dual LED Visibility: Features dual red LEDs ensuring 360-degree visibility for clear alarm indication.
  • Versatile Voltage Support: Compatible with DC 12V, 24V, and 48V operation across 2-wire and 4-wire models.
  • Auto-Reset Capability: Available 4-wire models feature auto-reset function for continuous monitoring.
  • Remote LED Output Option: 2-wire models available with remote LED output current up to 15mA.
  • N/O Alarm Relay Output: 4-wire models available with Normally Open alarm relay output for integration.
  • ISO and CE Certified: Products certified to ISO 9001:2008, EN, BSI, UL, and SGS standards.

Product Images of 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset

4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset pictures & photos
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset pictures & photos
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset pictures & photos
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset pictures & photos
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset pictures & photos
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset pictures & photos
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
  • 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
  • 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
    4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
  • 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
    4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
  • 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
    4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
  • 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
    4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
  • 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
    4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
  • 4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset
    4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset

Find Similar Products

Product Description

403 non-addressable photoelectric smoke detectors are state-of-the-art detectors suitable for connection to 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept non-addressable type detectors.
Advanced electronics in conjunction with a photoelectric smoke sensing chamber and an electronic thermistor provide early detection of fire and high immunity against unwanted alarms. 
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-ResetFeatures:

·    Photoelectric smoke sensor
·    Analogue detection discrimination
·    Dual LEDs for 360° visibility
·    2-wire and 4-wire models for DC 12 V and DC 24 V operation
·    4-wire model for DC 48 V operation
·    4-wire models available with a N/O alarm relay output
·    4-wire models available with auto-reset
·    2-wire models available with remote LED output
·    Connects to zone monitor for use with addressable control and indicating equipment
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-ResetSpecification:
operating voltage DC(12/24/48)V
start-up current ≤100μA
start-up time ≤30s
quiescent current 60μA
sampling time (3~5)s
alarm indicator Dual red LEDs
remote LED output current(max) 15mA
reset voltage ≤1V

Ordering Information:
Part Number 2-wire 4-wire Remote Indicator Relay Output Auto-Reset Sounder
403-006 √ - - - - -
403-007 √ - √ - - -
403-008 - √ - √ - -
403-009 - √ - √ - -
403-010 - √ - √ √ -
403-011 - √ - √ √ √
4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-ResetAbout Numens
Formed in 2010, Numens is an emerging supplier of professional safety products for fire detection and alarm systems. Numens supplies an extensive range of addressable, non-addressable and residential products for life safety and property protection applications. Offering over 150 products and supplying to more than 100 customers around the globe, we are committed to establishing long-term relationships with our customers and suppliers.
 
Mission and Values
Our mission is to provide building owners with high quality, inexpensive fire detection and related equipment that will protect lives of building occupants and minimize damage to buildings through early detection and warning of a fire emergency.
Our engineers, production and support staff will design, manufacture and deliver products with performance and quality to always delight our customers.
Success in our future depends on the integrity and ethical behaviour of all our employees. We support and nourish our staff to improve and grow as responsible members of a civil society. We take personal responsibility for our actions and respect others with different views, as we continually strive for improvements for our customers, our company and ourselves.
 
Capabilities
Sales, engineering and production are located in Ningbo, China; just 2 hours south of Shanghai. Our Ningbo site has 10,000 m2 (100,000 ft2) of floor-space. From product concept, electrical and mechanical design, we can provide the solutions to detection needs. Our manufacturing is vertically integrated, with our capabilities including tool-making, plastic injection moulding, SMT manufacturing, and final assembly and test.
You can view our product range on our website or in our product catalogue (document number 34-0001).
 
Standards and Approvals
Standards approvals are important to us, giving customers additional confidence of the performance and reliability of our products. We are certified to ISO 9001:2008 and our products carry approvals to major European and North American Standards.


FAQ:
Q1:Are you a manufacturer or trading company?
A1:Numens is a professional fire alarm system manufacturer.
 
Q2:What kind of production service do you provide?
A2:The whole fire alarm system,include Addressable system, Conventional system, Residential system and so on....
 
Q3:What kind of certification do you have?
A3:Numens was EN,BSI,UL,SGS certified and all the products were produced under these major international standard .
 
Q4:What is the lead time for new order?
A4:The lead time for new order is 25 days after confirm order.
 
Q5:How do I get price information?
A5:Sales representatives are responsible for providing detailed price information within 1 workday after get your inquiry.

4-Wire Fire Alarm Non-Addressable) Smoke Detector with Auto-Reset

About the Supplier

Watch Video
Watch Video
Ningbo Ambest Electronics Co., Ltd.
Ningbo Ambest Electronics Co., Ltd.
Ningbo Ambest Electronics Co., Ltd.
Ningbo Ambest Electronics Co., Ltd.
Ningbo Ambest Electronics Co., Ltd.
Ningbo Ambest Electronics Co., Ltd.
Ningbo Ambest Electronics Co., Ltd.
Ningbo Ambest Electronics Co., Ltd.

About Our Factory & Business Background

Address
55 Yunhui Road, Yunlong Town, Yinzhou district, Ningbo, Zhejiang, China 315137
Terms of Payment
T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Nearest Port
Ningbo,Shanghai

Our Production Capability & Technical Expertise

Main Products
Addressable Fire Alarm System, Non-Addressable Fire Alarm System, Residential Alarm Products, Heat Detector, Fire Alarm Control System, Gas Detector, Flame Detector, Fire Alarm, Conventional Smoke Detector, Addressable Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2012-02-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East

FAQ

Are you a manufacturer or trading company?
Numens is a professional fire alarm system manufacturer.
What kind of production service do you provide?
The whole fire alarm system, include Addressable system, Conventional system, Residential system and so on....
What kind of certification do you have?
Numens was EN,BSI,UL,SGS certified and all the products were produced under these major international standard .
What is the lead time for new order?
The lead time for new order is 25 days after confirm order.
How do I get price information?
Sales representatives are responsible for providing detailed price information within 1 workday after get your inquiry.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now